Today we attended to a reported leaking vinyl lined swimming pool in Gilston. We then introduced our Leaktrac 2400 to test the integrity of the vinyl walls and floor. We swept the liner twice which identified 8 holes on the vinyl floor. We entered the...

We then attended to a reported leaking shower in Eagleby. We first noticed the carpet was wet in the hallway adjacent to the shower leading into a bedroom. We conducted a series of tests which included water meter test, pressure test, shower breach test, drain...

We then attended to a reported leaking pebblecrete pool in Tarragindi, we first noticed the slab supporting the pump filtration system was not level and had subsided. We tested the multi port valve then set about pressure testing all concealed plumbing. We then entered the...

This morning we attended to a reported leaking Bathroom shower in Bray Park. We conducted a series of tests which included water meter test, pressure test, shower breach test, drain test, simulated shower test, vanity drain test and a shower base flood dye test. During...

We then attended to a reported leaking vinyl lined swimming pool in Wishart. We first tested the multiport valve we then introduced our Leaktrac 2400 to test the integrity of the vinyl walls and floor. We swept the liner twice which identified 2 holes on...

This morning we attended to a reported leaking ensuite shower in Daisy Hill. We conducted a series of tests which included water meter test, pressure test, shower breach test, drain test, simulated shower test, vanity drain test and a shower base flood dye test. ...

This morning we attended to a concealed water leak in Tingalpa, a water meter test revealed a leak of 2700 litres per day, a pressure test failed. After introducing a combination of compressed air and tracer gas we located the leak site being a...

We then attended to a reported leaking pebblecrete pool in Clear Island Waters. We tested the multi port valve before inspecting and dye testing the skimmer box, and return jets. We used a hydrophone microphone to test all penetrations. We then pressure tested both the...

This morning we attended to a reported leaking 100,000 litre pebblecrete pool in Carseldine. We tested the multi port valve then inspected and dye tested both skimmers. We then inspected a previously puttied vertical crack in the pebblecrete wall completed by another contractor. We found...