We then attended to a reported concealed water leak at a duplex in Coombabah. A water meter test revealed a leak of 822 litres per day, a pressure test failed after introducing compressed air into the line, we located a failed 25mm poly pipe under...

Yesterday we attended to a reported leaking fibreglass pool in Chlemer We tested the multi port valve before pressure testing all concealed plumbing. We identified a solar return provision was leaking adjacent to the house. Given the solar was not being used, the most cost...

We then travelled to a reported leaking concrete pool in Shailer Park. We tested the multi port valve before pressure testing the suction line. We then entered the pool inspected the main drain and replaced the hydrostratic valve. ...

This morning we attended to a concealed water leak on an acreage property in Sheldon, a water meter test revealed a leak of 10,800 litres per day. A pressure test failed. We introduced compressed air which identified the likely leak site being close to a...

We then attended to a concealed water leak in Cleveland, a water meter test revealed a leak of 43,200 litres per day. A pressure test failed. We introduced a combination of compressed air and tracer before obtaining a gas reading under a hedge close to...

This morning we attended to a reported leaking fibreglass pool in Warner, we inspected the pump filtration system before we pressure tested all possible concealed plumbing. We were unable to get the suction line to hold pressure. We tested the solar suction and solar return provisions...

We then attended to another leaking pool this time Kenmore Hills. We tested the multi port valve before pressure testing the suction line. We examined and dye tested the skimmer box before entering the pool and removing and dye testing the light cable and bracket. We...

This morning we attended to a reported leaking fibreglass swimming pool in Kenmore. We tested the multi port valve and found it to be leaking to waste. We installed an inline shit off valve before we pressure testing the concealed plumbing before entering the pool and...

We then attended to a newly installed pebblecrete pool in Woodend which the owner claims has been leaking since installed. We tested the Multi port valve before pressure testing all concealed plumbing which included suction , return and solar suction and solar return provisions. All...