Blog

We then attended to a swimming pool pre purchase inspection in Wishart, we first conducted a physical examination over the entire pool checking the concrete coping tile. We then hydrophoned the skimmer box, return jets, spa jets, light and main drain including the hydrostatic valve...

We then attended to a concealed water leak in Mt Gravatt East. We conducted a water meter test which indicated a leak of 960 litres per day. A pressure test failed after we traced the line we introduced compressed air before locating a leak in...

We then attended to conduct some pressure testing on the concealed plumbing at a concrete pool in Kenmore. We tested both the suction and return lines which held pressure. We tested the multi-port valve before entering the pool and dye testing the main drain including...

This morning we attended to a CCTV inspection in The Gap. Our client was concerned about some wetness close to his house after getting in a structural engineer to conduct an assessment. We access the sewer and stormwater drains from all areas around the affected...

We then attended to a reported vinyl swimming pool leak in Camira. We then used our Leaktrac 2400 to test the integrity of the pools vinyl liner. We swept the walls and floor twice which located a leak close to an existing pool patch and another...

We then attended a leaking pebblecrete pool in Bellbowie, our elderly client was certain she had a leak. We tested the multi port valve before pressure testing the concealed plumbing. The suction line held pressure but the return line failed. We located the leak in...

This morning we attended to a reported vinyl lined swimming pool leak in Bannockburn. We immediately commenced dye testing around the skimmer box, return jets and around the slate steps. We located a leak in the slate grouting. We then used our Leak trac 2400...

This morning we attended to a reported fibreglass swimming pool leak in Annerley. We first obtained background information then commenced to pressure test all the concealed plumbing which included the suction, return, solar in and solar out lines which all held pressure. We then checked...

Google Rating
4.9
Based on 237 reviews
js_loader
Google Rating
4.9
Based on 237 reviews
js_loader