Blog

This morning we attended to a reported leaking recently renovated swimming pool in Hawthorne We tested the multi port valve before hydrophone microphone all penetrations. We pressure tested the suction line before entering the pool and dye tested both lights. One of which was drawing dye around the...

This morning we attended and conducted CCTV inspection on a sewer line on a residential property in Strathpine. Our client had an engineer attend and conduct an inspection regarding some movement in the concrete around the property. We interred out camera and identified a number of...

This morning we attended to a reported leaking fibreglass pool in Narangba, using a CCTV camera we inspected the return jets to identify a cracked return housing. We dye tested which clearly showed dye escaping through the crack. We applied a epoxy putty bead to...

This morning we attended to a reported leaking pebblecrete pool in Eaton Hills. After getting the background from our client we set about conducting a series of tests which included hydrophone microphone testing of the penetrations which detected a sound of running water in the main...

This morning we attended to a reported concealed water leak in Mt Warren Park. A water meter test revealed a leak of 4320 litres per day. A pressure test failed. After tracing the line we introduced a combination of compressed air and tracer gas and...

We then attended to a reported leaking fibreglass pool in Alexandra Hills. We dye tested and inspected the return jets which appeared to be drawing in dye. We then used our CCTV camera and inspected and dye tested inside the the return jet to confirm...

This morning we attended to a reported concealed water leak in Alexandra Hills. A water meter test revealed a leak of 2700 litres per day. A pressure test failed. After tracing the line we introduced a combination of compressed air and tracer gas and identified...

This morning we attended to a reported leaking fibreglass swimming pool in Forest Lake. Our client had some insurance assessors attend and state the suction line around the skimmer box had failed. As such our client hired a concrete saw and removed a section of...

We then we attended to a reported leaking vinyl lined swimming pool in Capalaba. We tested the multi port valve, then we used our Leaktrac 2400 to test the integrity of the vinyl walls and floor. We swept the walls and floors twice before...

This morning we attended to a reported concealed water leak in Loganholme. A water meter test revealed a leak of 1542 litres per day. A pressure test failed after introducing compressed air into the leak we quickly located the leak being a failed 20mm copper...