This morning we attended to a reported sudden water loss in a large swimming pool in Sunnybank. Our client claimed she lost around 200mm over night. We tested the multi port valve before hydrophone microphone the skimmer boxes, return jets, lights and main drain including...

We then attended to a reported concealed water leak in Edens Landings, our client contacted us a couple of weeks ago at which time we referred her to her insurance company. The insurance company sent out a leak detector who marked a spot on the...

We then attended to a reported swimming pool leak in Birkdale, We tested the multi port valve before inspecting and dye testing the skimmer box. We then pressure tested the suction and return concealed plumbing. The Suction held pressure however the return did not. We introduced...

This morning we attended to a reported fibreglass swimming pool leak in Ashmore. We hydrophoned tested the skimmer, main drain and return jets. We noted the skimmer had been previously repaired, we checked the putty and re dye tested. We checked the return jets internals with a...

We then attended to a swimming pool in Bald Hills, our client was initially concerned his pool was leaking. We tested the pump filtration before inspecting and dye testing the skimmer box and face, inside all return & spa penetrations and the light. We removed...

This morning we attended to a reported leaking vinyl lined pool in Clontarf, we tested the multi port valve before using our Leaktrac 2440 to test the integrity of the vinyl liner. We swept the walls and floors twice before entering the pool and finding...

We then attended to a reported leaking fibreglass pool in Cleveland, we tested the multi port valve, inspected and dye tested the skimmer box. We used our hydrophone microphone to test the hydrostatic valve, main drain, skimmer box, spa jets x 3, light bracket and...

This morning we attended to a reported leaking vinyl lined in Rochedale South, we tested the multi port valve before inspecting and dye testing the skimmer box. We then used our Leak Trac 2400 to test the integrity of the vinyl liner. We then pressure...

We then attended to a reported leaking pebblecrete swimming pool in Wishart. We tested the suction concealed plumbing which held pressure. We then tested the solar suction provision which did not hold pressure. We introduced compressed air and could hear the sound of bubbling in the...

This morning we attended to conduct leak testing on a 12 month old pool in Stafford. We conducted a series of tests which included hydrophone and dye testing, pressure testing of all possible concealed plumbing. Before entering the pool and inspecting and removing the hydrostatic...