Blog

This morning we attended to a reported leaking concrete pool in Mt Warren Park. After obtaining background from our client we tested the skimmer box and the multi port valve before dye tested the return jets and spa . We noted the spa jets were...

This morning we attended to a reported leaking swimming pool return line in Brookefield. A previous contractor had attended but was unable to locate the leak site. We conducted a pressure test of the return line which failed to hold. We then introduced a combination...

We then attended to a reported vinyl lined swimming pool leak in Wellington Point. We checked the pump filtration/waste line under load before examining and dye testing the skimmer box. We then dye tested where our client had puttied over a leaking slate tile before...

This morning we attended to a reported leaking pool in Wellington Point. We were directed to water escaping from an electrical light conduit feeding a pool light. We entered the pool and removed the light fitting and dye tested and confirmed the leak site. We...

This morning we attended to a reported leaking pebblecrete pool in Beenleigh. We inspected the pump filtration system, then the. skimmer box before conducting a physical examination around the pool. We noted a previous puttied repair structural crack upon further inspection and dye testing confirmed...

We then attended to a reported fibreglass pool which was losing prime, we inspected the pump filtration system, replacing some o rings, we then inspected the skimmer box and noted some previous puttied areas noting what appeared to be a small crack at the base...

We then attended to a reported leaking fibreglass pool in Forest Lake, we tested the multi port valve and found it to be leaking to waste. We closed off the existing in line shut off valve. We then inspected the skimmer box noting some cracking....

We then attended to conduct a concealed water test and cctv inspection on the sewer and stormwater drains at a property in Warner. A structural engineer attended the property to investigate structural cracking inside the dwelling. We tested the water supply, then conducted CCTV inspection...