Leaking return line detected in a pebblecrete pool in Browns Plains

Leaking return line detected in a pebblecrete pool in Browns Plains

We the attended to a reported leaking pebbelecrete pool in Browwns Plains.
Our client was confident the problem was worse when the pump was operating.

We tested the multi port valve before pressure testing the suction line which held pressure.
We tested the return line which consisted of 3 x return jets which DID NOT hold pressure.

We introduced compressed air into the line and we could hear the sound of air bubbling away out of the damaged return pipe under the timber deck.

We showed our client our findings and gave him some instructions on the way forward to complete the repair in order to save further costs.