Fibreglass swimming pool leak testing at Warner

Fibreglass swimming pool leak testing at Warner

This morning we attended to a reported leaking fibreglass pool in Warner, we inspected the pump filtration system before we pressure tested all possible concealed plumbing. We were unable to get the suction line to hold pressure.
We tested the solar suction and solar return provisions which both held pressure.
We used a hydrophone microphone to test all penetrations which included the hydrostatic valve.

We entered the pool inspected and dye tested the skimmer face, light housing, hydrostatic valve and all penetrations.

We plugged the skimmer box and set up a bucket test to confirm the leak is in the suction line at which point our client will make contact with the pool builder for a warranty claim.

No Comments

Sorry, the comment form is closed at this time.