18 Oct Fibreglass swimming pool leak testing in Cleveland
We then attended to a reported leaking fibreglass pool in Cleveland, we tested the multi port valve, inspected and dye tested the skimmer box.
We used our hydrophone microphone to test the hydrostatic valve, main drain, skimmer box, spa jets x 3, light bracket and return jet.
We then pressure tested the suction and return lines which both held pressure. We were unable to test the spa return jets.
We then entered the pool and inspected, dye tested and replaced the hydrostatic valve.
We inspected and dye tested the skimmer box, main drain internal which was cracked, we applied epoxy to the internal fitting.
We inspected the internals of the return jet and this was also cracked, further putty was applied.
We then dye tested the spa jets x 3.
Sorry, the comment form is closed at this time.