We then attended to a reported leaking pebblecrete pool in Streeton, we tested the multi port valve before pressure testing the suction line which held pressure. We tested the return line which did not holding pressure. We were unable to test the spa line die to its plumbing configurations. We plugged the return jets and re directed the return line to waste which confirmed the spa line is heavily compromised.
We re directed the return line back to the return jets and supplied and installed 5 x 40mm flat plugs to isolate the spa jet.
We entered the pool and replaced the original hydrostatic valve.
We talked through our testing with our client.