This morning we attended to a reported leaking concrete pool in Bellbird Park, we first checked the pump filtration system before inspecting and dye testing the skimmer box, return jets x 3 . We then used a hydrophone microphone and checked all penetrations including the main drain. We entered the pool and inspected and dye tested the main drain including the hydrostatic valve which was leaking. We removed a large build up of calcium which encased the valve before replacing the 50mm hydrostatic valve.

 